Engineering:Short-circuit inductance

From HandWiki
Measurement of short-circuit inductance

Short-circuit inductance of a real linear two-winding transformer is inductance measured across the primary or secondary winding when the other winding is short-circuited.[1][Notes 1]  The method of measuring the short circuit inductance is described in industrial standard. The industrial standard also stipulates a method for obtaining the coupling factor by combining it with the open circuit inductance value.

Equivalent circuit

Measured primary and secondary short-circuit inductances may be considered as constituent parts of primary and secondary self-inductances. They are derived by using Ho-Thevenin's theorem from the equivalent inductance of the three-terminal equivalent circuit as follows. Then they are related according to the coupling factor as,

[math]\displaystyle{ L_{\mathrm{sc1}} = (1-k^2)\cdot L_{\mathrm{1}}\, }[/math]
[math]\displaystyle{ L_{\mathrm{sc2}} = (1-k^2)\cdot L_{\mathrm{2}}\, }[/math]

Where

  • k is coupling coefficient
  • L1 is primary self-inductance
  • L2 is secondary self-inductance

Short-circuit inductance measurement is used in conjunction with open-circuit inductance measurements to obtain various derived quantities like [math]\displaystyle{ k }[/math], the inductive coupling factor and [math]\displaystyle{ \sigma }[/math], the inductive leakage factor. [math]\displaystyle{ k }[/math] is derived according to:[Notes 2]

[math]\displaystyle{ k = \sqrt{1 - \frac{L_\text{sc}}{L_\text{oc}}} }[/math]

where

  • [math]\displaystyle{ L_\text{sc} }[/math] is the short-circuit measurement of primary or secondary inductance
  • [math]\displaystyle{ L_\text{oc} }[/math] is the corresponding open-circuit measurement of primary or secondary inductance

Other transformer parameters like leakage inductance and mutual inductance which cannot be directly measured may be defined in terms of k.

Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.